MLVSS Calculator

Mixed liquor suspended solids experiment
mL
Volume of mixed liquor filtered.
g
Tare of the prepared filter (plus dish, if weighed together).
g
After drying at 103–105 °C to constant weight.
Fixed solids experiment
mL
Leave blank when you ignite the same residue (Standard Methods 2540 E).
g
Empty crucible or dish (plus filter, if ignited together).
g
After ignition at 550 °C and cooling in a desiccator.
Solids in the tank (optional)
Adds the pounds and kilograms of MLSS and MLVSS under aeration.
Biology Updated 5 Nov 2026

Works out mixed liquor volatile suspended solids (MLVSS) for an activated sludge plant in two ways. In laboratory mode, enter the sample volume, the tare and dried weight of the filter (103–105 °C) and the tare and ignited weight of the crucible (550 °C) to get MLSS, fixed solids, MLVSS in mg/L and g/L and the volatile fraction, plus pounds and kilograms in the tank if you add its volume. In industrial mode, start from flow and primary effluent COD, or the COD load, and a target F/M ratio to find the MLVSS mass and concentration the aeration tank needs.

  • Weights are taken after cooling in a desiccator to constant weight; the calculator does not correct for filter blanks or weight lost by the filter itself on ignition.
  • In industrial mode the whole COD load reaches the aeration tank and the F/M ratio is on a COD basis per day.
  • US gallons are used for gallons; 8.34 lb per million gallons per mg/L is applied to US units as in operator practice.
  • This is a process-control aid; permit reporting must follow the approved laboratory method and your plant's QA procedures.

Formula

Laboratory: MLSS = (filter + residue − filter) ÷ sample volume; fixed solids = (crucible + ash − crucible) ÷ sample volume; MLVSS = MLSS − fixed solids. Industrial: flow (MGD) = flow (gal/h) × 24 ÷ 1,000,000; primary effluent COD = influent COD − COD removed in primary; COD added (lb/day) = flow (MGD) × primary effluent COD (mg/L) × 8.34; V = length × width × (sidewall depth − free-board); MLVSS (lb) = COD added ÷ F/M; MLVSS (mg/L) = MLVSS (lb) ÷ (V (gal) × 8.34 × 10⁻⁶).
  • Suspended solids are the residue caught on a glass-fibre filter and dried at 103–105 °C (Standard Methods 2540 D). Igniting that residue at 550 °C (2540 E, EPA Method 160.4) burns off the volatile, mostly biological, part and leaves the fixed ash.
  • With weights in grams and the sample in mL, mg/L = weight gain (g) × 1,000,000 ÷ sample volume (mL), the same as Standard Methods' (A − B) × 1,000 ÷ mL with weights in mg.
  • 8.34 is the weight in pounds of 1 mg/L dissolved in 1 million US gallons of water (3.785 L/gal × 1 mg = 8.345 lb rounded). It is used, as in US operator exams, whenever the flow, load or tank is in US units; metric inputs use kg = m³ × mg/L ÷ 1,000 exactly.
  • The F/M ratio here is pounds (or kg) of COD added per day per pound (or kg) of MLVSS under aeration, so MLVSS mass = COD load ÷ F/M. Plants that define F/M on BOD should enter a BOD load instead.
  • Activated sludge is usually about 65–85% volatile; a much lower fraction points to grit, chemical precipitate or an ignition problem.

MLVSS of a 50 mL mixed liquor sample

Inputs
  • Method: lab
  • Sample volume unit: mL
  • Weight unit: g
  • Sample volume: 50 mL
  • Weight of filter paper: 1.5432 g
  • Weight of filter paper + residue: 1.6582 g
  • Sample volume for fixed solids (optional): mL
  • Weight of crucible: 25.4321 g
  • Weight of crucible + ash: 25.4555 g
  • Aeration tank volume (optional):
  • Tank volume unit: gal
  • What do you know about the food supply?: flow
  • Flow: 2.5
  • Flow unit: mgd
  • Primary effluent COD: split
  • Average untreated influent COD: 400 mg/L
  • COD removed by primary treatment: 120 mg/L
  • Primary effluent COD: 280 mg/L
  • COD added to aeration: 3000
  • Load unit: lb
  • F/M ratio: 0.5 per day
  • Aeration tank volume: dims
  • Length unit: ft
  • Length: 120 ft
  • Width: 40 ft
  • Sidewall depth: 16 ft
  • Free-board: 2 ft
  • Aeration volume:
  • Volume unit: gal

The filter gains 1.6582 − 1.5432 = 0.1150 g of dry residue from 50 mL, so MLSS = 0.1150 g ÷ 0.050 L = 2.300 g/L = 2,300 mg/L. After ignition the crucible holds 25.4555 − 25.4321 = 0.0234 g of ash, so fixed solids = 0.0234 ÷ 0.050 = 468 mg/L. MLVSS = 2,300 − 468 = 1,832 mg/L, a volatile fraction of 1,832 ÷ 2,300 = 79.65%.

Sources & references

Frequently asked questions

What is the difference between MLSS and MLVSS?
MLSS is all the suspended solids in the aeration tank that stay on a filter and survive drying at 103–105 °C. MLVSS is the part of them that burns off at 550 °C, which is mostly microorganisms and other organic matter. MLVSS = MLSS − fixed (ash) solids; for example 2,300 mg/L MLSS with 468 mg/L of ash leaves 1,832 mg/L MLVSS.
How do I calculate MLVSS from the F/M ratio?
Work out the COD load as flow (MGD) × primary effluent COD (mg/L) × 8.34, then divide by the F/M ratio. A plant treating 2.5 MGD at 280 mg/L COD receives 5,838 lb/day; at an F/M of 0.5 it needs 11,676 lb of MLVSS under aeration. Divide by the tank volume in million gallons and by 8.34 to get mg/L.
What is the MLVSS when the COD load is 3,000 lb per day and the F/M ratio is 0.65?
3,000 ÷ 0.65 = 4,615 lb of MLVSS. In a 0.5 million gallon tank that is 4,615 ÷ (0.5 × 8.34) = 1,107 mg/L.
What is a normal MLVSS to MLSS ratio?
Most municipal activated sludge is about 0.65–0.85 (65–85%) volatile. Extended aeration plants with long sludge ages and plants dosing iron, aluminium or lime for phosphorus removal tend to sit at the lower end, because inorganic solids build up.
Can I ignite the same filter I used for MLSS?
Yes, that is the Standard Methods 2540 E procedure: the dried filter and residue from the suspended solids test are ignited at 550 °C. Enter the filter-and-dish tare as the crucible weight and the ignited weight as crucible + ash, and leave the second sample volume blank.