DNA Concentration Calculator

Sample
Measurement
Blank-corrected reading at the absorbance maximum (260 nm for nucleic acids).
Standard cuvettes are 1 cm. Most microvolume readers report values already normalised to 1 cm.
Total volume ÷ sample volume of the dilution you measured. Leave at 1 for an undiluted sample.
Purity and yield (optional)
Optional. Gives the A₂₆₀/A₂₈₀ ratio.
Optional. Gives the A₂₆₀/A₂₃₀ ratio.
Optional. Volume of the undiluted stock, for the total yield.
Biology Updated 29 Oct 2026

Turns a UV spectrophotometer reading into a nucleic acid concentration. Enter the absorbance at 260 nm, the cuvette path length and any dilution factor, and pick double-stranded DNA (50 µg/mL per A₂₆₀), single-stranded DNA (33), RNA (40), your own conversion factor, or a custom oligonucleotide. For an oligo, paste its sequence and the calculator works out the molecular weight and the nearest-neighbour extinction coefficient, or type both values in. Optional A₂₈₀ and A₂₃₀ readings give the purity ratios, and a sample volume gives the total yield.

  • Absorbance is blank-corrected and within the linear range of the instrument.
  • The fixed factors assume pure nucleic acid of average base composition; all absorbance at 260 nm is attributed to the selected nucleic acid.
  • Oligo calculations treat the molecule as a single strand without modifications, dyes or modified bases, which change both mass and ε₂₆₀.
  • Purity thresholds are common rules of thumb; ratios depend on buffer pH and ionic strength.

Formula

C = (A₂₆₀ ÷ l) × CF × DF. CF = 50 µg/mL (dsDNA), 33 µg/mL (ssDNA), 40 µg/mL (RNA); for an oligo CF = MW ÷ ε₂₆₀. ε₂₆₀ = Σ ε(nearest-neighbour pairs) − Σ ε(internal bases). Molar concentration = A₂₆₀ × DF ÷ (ε₂₆₀ × l)
  • C is the concentration of the undiluted stock, A₂₆₀ the blank-corrected absorbance, l the path length in centimetres and DF the dilution factor (total volume ÷ sample volume).
  • The conversion factor CF is the concentration that gives A₂₆₀ = 1.0 over 1 cm. The calculator uses 50, 33 and 40 µg/mL for dsDNA, ssDNA and RNA, the standard values used by most instrument software.
  • For an oligo, Beer–Lambert gives the molar concentration A ÷ (ε × l); multiplying by the molecular weight turns it into mass per volume. MW ÷ ε is in mg/mL per absorbance unit, so it is multiplied by 1000 to give µg/mL.
  • Molecular weight from the sequence: ssDNA residues A 313.21, C 289.18, G 329.21, T 304.20 g/mol; RNA residues A 329.21, C 305.18, G 345.21, U 306.20 g/mol. The 5′-end correction is −61.96 g/mol with no phosphate, +17.04 g/mol with a 5′ monophosphate and +159.0 g/mol with a 5′ triphosphate.
  • Extinction coefficient from the sequence: the nearest-neighbour model adds ε for every adjacent pair (read 5′→3′) and subtracts ε for each base except the two ends. DNA uses the standard DNA table (A 15,400, C 7,400, G 11,500, T 8,700). RNA uses the standard RNA table (A 15,400, C 7,200, G 11,500, U 9,900), which differs from DNA for C-containing pairs and is direction-specific for U pairs.
  • Purity: A₂₆₀/A₂₈₀ ≈ 1.8 suggests clean DNA and ≈ 2.0 clean RNA; A₂₆₀/A₂₃₀ is expected around 2.0–2.2. These are rules of thumb, not pass/fail limits.
  • Total yield = C (µg/mL) × total sample volume (mL).

dsDNA, A₂₆₀ = 0.65 in a 1 cm cuvette after a 1:20 dilution

Inputs
  • Sample type: dsdna
  • Oligo properties: sequence
  • Oligo type: dna
  • 5′ end: oh
  • Sequence (5′→3′): AGGTC
  • Absorbance at 260 nm (A₂₆₀): 0.65
  • Path length: 1
  • Path length unit: cm
  • Dilution factor: 20
  • Show concentration in: ugml
  • Absorbance at 280 nm (A₂₈₀): 0.35
  • Absorbance at 230 nm (A₂₃₀): 0.31
  • Total sample volume: 50
  • Volume unit: ul

C = 0.65 ÷ 1 × 50 × 20 = 650 µg/mL, which is 650 ng/µL. A₂₆₀/A₂₈₀ = 0.65 ÷ 0.35 = 1.86, close to the 1.8 expected for clean DNA, and A₂₆₀/A₂₃₀ = 0.65 ÷ 0.31 = 2.10, inside the usual 2.0–2.2. The 50 µL stock therefore holds 650 × 0.05 = 32.5 µg of DNA.

Sources & references

Frequently asked questions

Why are the conversion factors 50, 33 and 40 µg/mL?
They are the concentrations that give an absorbance of 1.0 at 260 nm over 1 cm. Double-stranded DNA absorbs less per gram than single strands because stacked, paired bases absorb less UV (the hypochromic effect), so more of it is needed to reach A₂₆₀ = 1. Some labs use 37 µg/mL for ssDNA; choose 'Other conversion factor' to use any value.
How do I calculate the concentration of a primer or other oligo?
Short oligos vary too much in base composition for a fixed factor. Choose 'Custom oligonucleotide' and paste the sequence: the calculator adds up the residue masses for the molecular weight and uses the nearest-neighbour model for ε₂₆₀. If your synthesis report lists ε₂₆₀ and the molecular weight, type those in instead; manufacturers sometimes use slightly different tables.
What does the A₂₆₀/A₂₈₀ ratio tell me?
Nucleic acids absorb about twice as strongly at 260 nm as at 280 nm, while proteins absorb most near 280 nm. A ratio near 1.8 for DNA or 2.0 for RNA suggests little protein or phenol. Low ratios point to contamination; the ratio also shifts with buffer pH, so measure in a slightly alkaline, low-salt buffer for consistent results.
What does the A₂₆₀/A₂₃₀ ratio mean?
Many extraction reagents, such as guanidine salts, EDTA, phenol and carbohydrates, absorb near 230 nm. A clean sample usually gives 2.0–2.2. A low value warns that the A₂₆₀ reading, and therefore the concentration, may be inflated by carry-over.
What absorbance range gives reliable results?
Most spectrophotometers are most accurate when the reading lies roughly between 0.1 and 1.0 absorbance units in a 1 cm cuvette. Dilute concentrated samples and enter the dilution factor; very low readings are better measured with a fluorescent dye assay.
Do I need to change the path length for a NanoDrop?
Usually not. Microvolume instruments measure over very short paths (often 1 mm or less) but report absorbance normalised to 1 cm. Enter a shorter path only if your instrument gives the raw absorbance for that path.
How do I get the total amount of DNA in my tube?
Multiply the concentration by the total volume of the undiluted stock: µg = µg/mL × mL. Enter the sample volume in the optional field and the calculator shows the yield.

Related calculators

DNA Copy Number Calculator Converts a DNA or RNA concentration into the number of template molecules per microlitre, or a mass of DNA into a total number of copies. Enter the concentration (or mass), the template length and whether the template is double-stranded DNA, single-stranded DNA or RNA; the calculator applies Avogadro's constant and the average mass per base pair. An optional dilution helper tells you how much stock and water to mix for a target copies/µL, and the PCR section estimates copies after a number of cycles, or the cycles needed to reach a target, at any amplification efficiency. Ligation Calculator Works out how much insert DNA to add to a ligation for a chosen insert:vector molar ratio, or how much vector goes with a given amount of insert. Enter the insert and vector lengths in bp or kb, the mass you already have, and a ratio such as the common 3:1. The calculator scales the mass by the length ratio, shows the moles of each fragment, the total DNA in the reaction and, if you enter the stock concentrations, the volume of each to pipette. Protein Concentration Calculator (A280) Turns a UV absorbance reading (usually A280) into a protein concentration with the Beer–Lambert law. Pick a common protein such as BSA, IgG or lysozyme, or enter your own extinction coefficient as a molar value (M⁻¹cm⁻¹), as the absorbance of a 1 mg/mL solution, or as E1%. Add the cuvette path length in cm or mm and any dilution factor, and get the concentration in mg/mL, µg/mL and molar units. Molarity Calculator Calculates the molarity of a solution, or works backwards to the mass of solute or the volume of solution you need for a target molarity. Molarity is the amount of dissolved substance in moles per litre of solution (mol/L, written M). Enter the molar mass with the mass of solute and the final volume, a target molarity, or a mass concentration in g/L, and get the molarity, moles of solute and concentration. Annealing Temperature Calculator Finds the optimal PCR annealing temperature with the Rychlik formula Ta = 0.3 × Tm(primer) + 0.7 × Tm(product) − 14.9. Enter the melting temperature of the less stable primer and of the PCR product in °C, °F or K, or paste both primer sequences and let the calculator work out each primer's Tm (nearest-neighbour, salt-adjusted or basic method) and the product Tm from its length and GC content at your salt concentration. It also flags primer pairs whose melting temperatures differ by more than 5 °C.